When users log in to a computer that is a domain member, they may encounter the following error.
The Security database on the server does not have a computer account for this workstation trust relationship
This error usually occurs when the domain network has not been logged on for a long time or when Computer ADUC (Active Directory It is encountered when the system is deleted or disabled via Users and Computers.
Table of Contents
Preliminary Checks for Workstation Trust Relationship
Before moving on to the solution, you need to check the replication status and clock information of your DC (Domain Controller) servers. These steps can help you identify the source of the problem.
Solution to Workstation Trust Relationship Error
For solution ADUC in the relevant computer object via dNSHostName ve servicePrincipalName You need to check the attributes.
Attribute Control via ADUC:
- Find the relevant computer object via ADUC (Active Directory Users and Computers).
- This object contains
dNSHostName
veservicePrincipalName
check the attributes.
Attribute Matching:
dNSHostName
veservicePrincipalName
values must match the computer name.- If these values do not match, you can edit them manually.
Replication and Restart:
- After making the adjustments, wait for the relevant servers to perform the replication process.
- Restart the client computer and check if the issue is resolved.
One comment on “Active Directory Computer Account for this Workstation Trust Relationship”